Search results for "STRAIN GAUGE"

showing 10 items of 52 documents

Experimental Method for Determining Forces at Bending of Perforated Plates

2017

Abstract This paper describes the method of calculating the forces which appear at the bending of perforated plates with holes of different shapes and placed in different patterns, by means of a dynamometric table which uses resistive tensometric transducers (strain gauges). It also describes an instrument for the recording of data from the dynamometric table, a tool created with the aid of the “TestPoint” software which, beneath the data recording, ensures the filtering and statistic processing of data. The obtained results are displayed in comparative graphs for six types of perforated plates, as well as for an unperforated plate.

Materials scienceTransducerGeneral MedicineBendingComposite materialStrain gaugeACTA Universitatis Cibiniensis
researchProduct

Ticlopidine in the Treatment of Multiple Atherosclerotic Arteriopathy: a Strain Gauge Plethysmography and Döppler Spectrum Analysis Evaluation

1987

The effect of ticlopidine was compared with flunarizine in patients with iliac–femoral and / or femoral–popliteal arteriosclerotic arteriopathy accompanied by lesions of the cervical arteries of no haemodynamic significance. In the lower limbs, plethysmography (strain gauge measurements) and Döppler ultrasonography integrated by spectral analysis of the cervical arteries showed qualitative and quantitative improvements of the regional haematic flow. Side-effects were negligible which suggests that ticlopidine is useful in the treatment of multiple arteriosclerotic arteriopathy.

medicine.medical_specialtyPathologyTiclopidineArteriosclerosisCervical ArteryHemodynamics030204 cardiovascular system & hematologyBiochemistry03 medical and health sciencessymbols.namesake0302 clinical medicineInternal medicineHumansMedicinePlethysmograph030212 general & internal medicineTiclopidineFlunarizineAgedUltrasonographybusiness.industryVascular diseaseBiochemistry (medical)Cell BiologyGeneral MedicineMiddle Agedmedicine.diseasePlethysmographyCardiologysymbolsbusinessDoppler effectBlood Flow VelocityFlunarizinemedicine.drugStrain gauge plethysmographyJournal of International Medical Research
researchProduct

The importance of correct implants positioning and masticatory load direction on a fixed prosthesis

2018

Background Through the biomechanical study of dental implants, it is possible to understand the dissipation effects of masticatory loads in different situations and prevent the longevity of osseointegration. Aims: To evaluate the microstrains generated around external hexagon implants, using axial and non-axial loads in a fixed four-element prosthesis with straight implants and implants inclined at 17°. Material and Methods Three implants were modeled using CAD software following the manufacturer's measurements. Then, implants were duplicated and divided into two groups: one with straight implants and respective abutments, and the other with angled implants at 17° and respective abutments. …

Fixed prosthesisMaterials sciencemedicine.medical_treatment0206 medical engineering02 engineering and technologyProsthesisOsseointegrationHealth Services AccessibilityStress (mechanics)03 medical and health sciences0302 clinical medicineBiomaterials and Bioengineering in DentistrymedicineChildGeneral DentistryPovertyStrain gaugeOrthodonticsResearch030206 dentistryIn vitro experiment:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringFinite element methodMasticatory forceUNESCO::CIENCIAS MÉDICASDental caries
researchProduct

Lay-up optimization for the hull of a racing sailing yacht

2001

Abstract Deformability and buckling load of yacht hulls with fiber reinforced plastic sandwich structure depend on the stack sequence of the skins. In this work an optimization of fiber directions of the laminae for a racing yacht is proposed. This procedure has been divided into three parts (i.e. material characterization, surface model definition, lay-up optimization). First of all a set of unidirectional specimens has been realized, by using the same fibers and matrix (carbon/epoxy) used for the hull as well as the same procedure and workers, in order to characterize the material according to American Society for Testing and Materials (ASTM) Standard D3039, employing strain gage techniqu…

Engineeringbusiness.industryGeneral EngineeringComputational MechanicsStructural engineeringFibre-reinforced plasticFinite element methodSoftware; Computational MechanicsMatrix (mathematics)Stack (abstract data type)BucklingHullComputational mechanicsbusinessStrain gaugeSoftware
researchProduct

Passive RFID Strain-Sensor Based on Meander-Line Antennas

2011

The processing of backscattered signals coming from RFID tags is potentially useful to detect the physical state of the tagged object. It is here shown how to design a completely passive UHF RFID sensor for strain monitoring starting from a flexible meander-line dipole whose shape factor and feed section are engineered to achieve the desired sensing resolution and dynamic range. This class of devices is low-cost, promises sub-millimeter resolution and may found interesting applications in the Structural Health Monitoring of damaged structures and vehicles as well as during extreme and adverse events.

BackscatterComputer sciencebusiness.industryElectrical engineeringSettore ING-INF/02 - Campi Elettromagneticilaw.inventionDipoleRFID sensor SHMUltra high frequencylawDipole antennaStructural health monitoringSensitivity (control systems)Electrical and Electronic EngineeringbusinessElectrical impedanceStrain gauge
researchProduct

Influence of different restorative materials on the stress distribution in dental implants

2018

Background To assist clinicians in deciding the most suitable restorative materials to be used in the crowns and abutment in implant rehabilitation. Material and methods For finite element analysis (FEA), a regular morse taper implant was created using a computer aided design software. The implant was inserted at the bone model with 3 mm of exposed threads. An anatomic prosthesis representing a first maxillary molar was modeled and cemented on the solid abutment. Considering the crown material (zirconia, chromium-cobalt, lithium disilicate and hybrid ceramic) and abutment (Titanium and zirconia), the geometries were multiplied, totaling eight groups. In order to perform the static analysis,…

Materials sciencemedicine.medical_treatmentceramic0206 medical engineeringAbutment02 engineering and technologyCrown (dentistry)Stress (mechanics)03 medical and health sciences0302 clinical medicinestomatognathic systemdental implantsBiomaterials and Bioengineering in DentistrymedicineCeramicComposite materialGeneral DentistryElastic modulusStrain gaugeStress concentrationResearchFinite element analysis030206 dentistry:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumImplantJournal of Clinical and Experimental Dentistry
researchProduct

Vibration Detector based on GMR Sensors

2007

Up to now, vibrations have been mostly sensed by measuring displacement, velocity and acceleration. The most common types of vibration sensors are piezoelectric, capacitive, null-balance, strain gage, optoelectronic, resonance beam or piezoresistive. We present a low cost and low power vibration detector based on the measurement of magnetic field variations induced in a recent SS501 GMR magnetic sensor, which has never been applied for that. Vibrations on small ferromagnetic pieces disturb the Earth's magnetic field. These weak perturbations can be detected and measured over the assumed constant Earth's magnetic field, which is uniform over a wide area. A novel array configuration of 3 half…

PhysicsVibrationEarth's magnetic fieldMagnetoresistancebusiness.industryCapacitive sensingAcousticsDetectorElectrical engineeringbusinessPiezoresistive effectStrain gaugeMagnetic field2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007
researchProduct

Stiffness and Reinforcement Effect of electrical Resistance Strain Gauges

2007

:  The increasing use of low-modulus materials, on which the reinforcement effect of the electrical resistance strain gauge is not negligible, has re-opened the research interest into this issue. This study deals with the evaluation of stiffness, and of the strain gauge Young's modulus involved in the estimation of both the global and the local reinforcement effect; the relationship between the strain gauge stiffness and the local reinforcement effect is also analysed. In particular, the experimental technique used to determine the stiffness of some commercial strain gauges is described. The results show that the strain gauge stiffness alone does not permit an accurate evaluation of the loc…

musculoskeletal diseasesanimal structuresMaterials sciencebusiness.industryMechanical Engineeringtechnology industry and agricultureModulusStiffnessStructural engineeringequipment and suppliesmusculoskeletal systemexperimental mechanicreinforcement effectSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineElectrical resistance and conductancestrain gaugesMechanics of MaterialsmedicineSettore ING-IND/12 - Misure Meccaniche E Termichemedicine.symptomComposite materialReinforcementbusinessStrain gaugestiffne
researchProduct

Determination of the residual stresses in composite laminate using the compliance method

2005

Residual stresses play an important role on the mechanical behavior of composite laminate. The development of new methods to determine the residual stresses gradient within the laminates is necessary. This article presents the adaptation of the compliance method in the case of composite laminates carbon/epoxy [02/902]s. The incremental drilling of a constant width groove allows for each increment to measure the strains (using strain gages) and displacements (using an optical device) of particularly points of the structure surface. These experimental data are compared with results given by a finite elements simulation. This comparison allows to raise the residual stresses in the composite la…

Materials science[SPI] Engineering Sciences [physics]Composite number02 engineering and technologyCompliance method[SPI]Engineering Sciences [physics]0203 mechanical engineeringResidual stress[SPI.MECA.MEMA]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanics of materials [physics.class-ph]General Materials ScienceComposite materialStrain gaugeGroove (music)ComputingMilieux_MISCELLANEOUSbusiness.industryMechanical EngineeringEpoxyStructural engineeringComposite laminates021001 nanoscience & nanotechnologyCondensed Matter PhysicsFinite element method020303 mechanical engineering & transportsMechanics of Materialsvisual_artvisual_art.visual_art_medium0210 nano-technologybusiness
researchProduct

Effects of clearance on thick, single-lap bolted joints using through-the-thickness measuring techniques

2011

Composite materials have increasingly become more common in ground transportation. As this occured thicker panels, as compared to composite panels used in aviation, become necessary in order to withstand high impact loads and day to day degradation. The effectiveness of these panels was often limited by the strength of the joint in which the panel was attached to the frame of the vehicle. Investigating methods of reducing strain concentrations within these joints would increase the effectiveness in using composite materials in ground transportation applications by increasing the load necessary for joint failure to occur. In this study, fiber optic strain gages were embedded in a composite p…

Optical fiberBearing (mechanical)Materials scienceStrain (chemistry)lawComposite plateBolted jointComposite numberComposite materialcomposites lap-joints fiber optic strain gage finite element analysisJoint (geology)Strain gaugelaw.invention
researchProduct